[1]韩晓维,包中进,陈益彬,等.瓯飞一期围垦工程北1#闸消能试验研究[J].浙江水利科技,2015,(01):010-13.[doi:10.13641/j.cnki.33-1162/tv.2015.01.003]
 HAN Xiao-wei,BAO Zhong-jin,CHEN Yi-bin,et al.The North Gate#1 Energy Dissipation Experimental Study of Oufei First Phase Reclamation Project[J].Zhejiang Hydrotechnics,2015,(01):010-13.[doi:10.13641/j.cnki.33-1162/tv.2015.01.003]
点击复制

瓯飞一期围垦工程北1#闸消能试验研究
分享到:

《浙江水利科技》[ISSN:1008-701X/CN:33-1080/TV]

卷:
期数:
2015年01期
页码:
010-13
栏目:
出版日期:
2015-01-25

文章信息/Info

Title:
The North Gate#1 Energy Dissipation Experimental Study of Oufei First Phase Reclamation Project
作者:
韩晓维1 包中进1 陈益彬2 吕有畅2
1. 浙江省水利河口研究院, 浙江 杭州 310020;
2. 温州市瓯飞开发建设管理委员会, 浙江 温州 325000
Author(s):
HAN Xiao-wei1 BAO Zhong-jin1 CHEN Yi-bin2 LV You-chang2
1. Zhejiang Institute of Hydraulics & Estuary, Hangzhou 310020, Zhejiang, China;
2. Wenzhou Oufei development and construction management committee, Wenzhou 325000, Zhejiang, China
关键词:
瓯飞一期围垦工程滨海水闸水工模型无翼墙消能池消能率
Keywords:
Oufei reclamation projectmarina sluicehydraulic modelnon-wingwall stilling basihenergy dissipation rate
分类号:
TV131.6
DOI:
10.13641/j.cnki.33-1162/tv.2015.01.003
摘要:
北1#闸位于瓯飞一期围垦工程瓯江侧为I等工程,其外海侧潮差大,运行工况复杂.而水闸本身属低水头、低佛汝德数消能,消能率不高,故消力池型式的优化设计对大闸安全显得尤为重要.通过1∶50整体水工模型详细研究了无翼墙二级消力池的布置型式,对闸下消能方案进行了比选,并从水流流态、闸下冲刷等方面综合考虑,提出了适合该工程的消能布置型式,试验表明该布置型式可以有效地解决闸下水深不足时的水流衔接问题.
Abstract:
North Gate # 1 located on Oujiang side of Oufei first phase reclamation project, off the coast side large tidal range, complex operating conditions, sluice itself is low water head, low Froude number and energy dissipation rate is not high, so the optimal design of stilling basin type is very important for sluice safety.Detailed study the wingless wall two stilling basin layout pattern by the 1:50 overall hydraulic model, compare and select the brake energy dissipation scheme, and integrated considering the flow pattern, under sluice scour etc., proposed the suitable energy dissipation layout pattern for the project.Tests showed that the layout pattern can effectively solve the water interface issues when the water depth is short under the gate, the research results can provide reference for similar projects.

参考文献/References:

[1] 中华人民共和国水利部.SL 256—2001水闸设计规范[S].北京:中国水利水电出版社,2001.
[2] 潘世虎.水闸底流消能计算公式的分析与改进[J].人民黄河,2012,34(4):119-120.
[3] 张斌,陈香香,徐鹏,等.关于水闸下游无水工况的消能计算探讨[J].水利水电工程设计,2012,31(4):19-20.
[4] 车传金,和秀芬,李聚兴.软基上高水头退水闸底流消能方案研究与设计优化[C] //河海大学出版社:第三届全国水力学与水利信息进展(南京),2007:273-277.
[5] 周玉香,翟召华,季新民,等.低Fr数消能规律研究[J].山东大学学报:工学版,2005,35(4):80-84.
[6] 陆芳春,史斌,林军.曹娥江大闸枢纽工程消能试验研究[J].浙江水利科技,2004(6):35-37.
[7] 马孟华,石萍,张丽.平原进洪闸消能试验研究[J].中国农村水利水电,2007(9):103-105.
[8] 梁跃平,刘海凌,梁国亭.辅助消能工应用于低佛氏数水流消能的试验研究[J].华北水利水电学院学报,2000,21(1):14-16.

备注/Memo

备注/Memo:
收稿日期:2014-8-11;改回日期:。
基金项目:浙江省科研院所专项基金(2012F20030);浙江省水利科技计划项目(RA1402).
作者简介:韩晓维(1985-),男,工程师,硕士,主要从事水工水力学研究工作.E-mail:hanxiaowei_abc@163.com
更新日期/Last Update: 1900-01-01